Summary for Test 2024-05-29-128-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 215240
DEA: 021H6804
EFIS: 0216000010
DIST-CO-RTE-PM02-TEH-5-39/41.9
Award Date02/13/2023
Closeout Date09/22/2025
Work DescriptionSB Cottonwood Scales
Location DescriptionNot set
QA Service Level1 (Verified on 10/23/2020)

Sample Information

Sample Taken Date05/29/2024 Sample Unique Key128
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2024
Sample typeProduction Start-Up A brief description of the sample3 bags of Combined Lime Treated 3/4-inch Type G Aggregate
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET NRC Telephone number of sampler
Laboratory sample identificationD79561 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number035798
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0061::Latona Aggregates/91-45-0057::Shasta Ranch Agg.
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2025-02-2: JMF 24-11-P0112024-05-29-128-1

Test Details

DIME Sample ID: 2024-05-29-128
DIME Test ID: 2024-05-29-128-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-02-07

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 06/05/2024
Cumulative Mass RetainedCumulative Percent Passing
5089.2 grams
grams %
0.0 grams100 %
0.0 grams100 %
71.0 grams99 %
869.0 grams83 %
1784.0 grams65 %
3571.0 grams30 %
492.1 grams
215.6 grams17 %
305.9 grams11 %
356.7 grams8 %
390.0 grams6 %
414.3 grams5 %
432.2 grams3.7 %
436.7 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/7/2025