Summary for Test 2024-11-27-21-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214698
DEA: 120N8904
EFIS: 1214000130
DIST-CO-RTE-PM12-ORA-133-8.3/M9.3
Award Date11/09/2023
Closeout DateNot set
Work DescriptionCONSTRUCT AUXILIARY LANE.
Location DescriptionORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
QA Service Level1 (Verified on 02/22/2021)

Sample Information

Sample Taken Date11/27/2024 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing11/28/2024 Sample typeQuality Control
A brief description of the sample4x8 Cylinders The quantity of what the sample constitutes9
From where was the sample collectedJob Site First name of sampler or witnessed byGeroge
Last name of sampler or witnessed byZacarias Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identificationSet 1
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJob Site
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS63C453T14
The truck number from where the sample was collectedLoad 2 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedRTE 133 Bridge, RW 61, STEM, STA 11+68 - 11+92 Where the material sample would have been placed if not sampledUnknown
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2024-11-27-21
DIME Test ID: 2024-11-27-21-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-03-21

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Isaac Vasquez
Date of test: 12/04/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 48444 lb
Maximum load on cylinder 2: 44976 lb
Maximum load on cylinder 3: 47565 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 3740 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2025