Summary for Test 2025-01-30-12-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000144
DEA: 061E2204
EFIS: 0621000227
DIST-CO-RTE-PM06-FRE-180-R65.3/R66.3
Award Date05/03/2024
Closeout Date07/14/2025
Work DescriptionHIGH TENSION CABLE BARRIER AND VEGETATION CONTROL.
Location DescriptionFRESNO COUNTY NEAR FRESNO FROM TEMPERANCE AVENUE UNDERCROSSING TO 0.1 MILE WEST OF DE WOLF AVENUE.
QA Service Level1 (Verified on 03/04/2024)

Sample Information

Sample Taken Date01/30/2025 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing01/31/2025 Sample typeQuality Assurance
A brief description of the sampleconcrete The quantity of what the sample constitutes9 CY
From where was the sample collectedJob Site First name of sampler or witnessed byAdam
Last name of sampler or witnessed byMahmoud Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1416245
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected41108769
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-01-30-12
DIME Test ID: 2025-01-30-12-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-02-07

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 02/07/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 47030 lb
Maximum load on cylinder 2: 44140 lb
Maximum load on cylinder 3: 45380 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3741.4 psi
Compressive strength of cylinder 2: 3511.5 psi
Compressive strength of cylinder 3: 3610.2 psi
Compressive strength (to nearest 10 psi): 3620 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/7/2025 ✔