Summary for Test 2025-01-06-46-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/06/2025 Sample Unique Key46
Date that the sample was received by the laboratory/organization performing the testing01/06/2025 Sample typeQuality Control
A brief description of the sampleAsphalt Binder The quantity of what the sample constitutes1 of 2 cans
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byConner Title of sampler
Telephone number of sampler Laboratory sample identification6416250106
Linked DIME Sample ID The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number6415250106
Sublot number Tank number32-1
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-01-06-46
DIME Test ID: 2025-01-06-46-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-02-06

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 01/06/2025
Observed Flash Point: 527 F
Ambient Barometric Pressure: 732 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 527 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/6/2025 ✔