Summary for Test 2025-01-04-3-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date01/04/2025 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/07/2025 Sample typeAcceptance
A brief description of the sample1x4 and WCS The quantity of what the sample constitutes120 cy
From where was the sample collectedManufacturer First name of sampler or witnessed byvictor
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler2137924794 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMyers and Sons Construction
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the samplemix vtc675
The plant numberwhittier plant A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberVTCS675 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-01-04-3
DIME Test ID: 2025-01-04-3-4
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-03-11

Test Results


Number of tests: 2
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 01/07/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.8
Sand reading (test 1): 4.1
Clay reading (test 2): 4.8
Sand reading (test 2): 4
Sand equivalent (test 1): 86
Sand equivalent (test 2): 84
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2025 ✔