Summary for Test 2024-10-21-2-2

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 994673
DEA: 033F0704
EFIS: 0312000054
DIST-CO-RTE-PM03-SAC-51-2.0/3.5
Award Date08/17/2023
Closeout DateNot set
Work DescriptionAmerican River Bridge Rehabilitation
Location DescriptionNot set
QA Service Level1 (Verified on 05/15/2023)

Sample Information

Sample Taken Date10/21/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2024
Sample typeQuality Assurance A brief description of the sampleTwo (2) 1-3/8" Threaded Bar, four (4) 1-3/8" Nuts, and four (4) washers
The quantity of what the sample constitutesFour (4) Threaded Bars From where was the sample collectedSupplier
First name of sampler or witnessed byPreston Last name of sampler or witnessed byBrockett
Title of samplerCT METS QA INSPECTOR Telephone number of sampler5627836180
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWilliams Form Engineering San Diego Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL175-157-24 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size
Nut Specification for Threaded BarASTM A29 System ManufacturerWilliams Form Engineering San Diego
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)58052325/04
Nut Heat Number(s)20762050 Bar Lot Number04
Nut Lot Number36G9D Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2024-10-21-2
DIME Test ID: 2024-10-21-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2025-02-03

Test Results


Number of Threaded Bar Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 02/03/2025
UTM: NA
Temperature: 0 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
110580523251.58166900130300700Atlas
220580523251.58164500145200700Atlas
330580523251.581595001330009320Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/3/2025