Summary for Test 2025-01-27-7-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000259 DEA: 050N74V4 EFIS: 0522000043 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-9.2/9.7 |
| Award Date | 02/08/2024 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | FOR CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY AT MONTECITO FROM 0.2 MILE NORTH OF SHEFFIELD DRIVE UNDERCROSSING TO 0.3 MILE SOUTH OF SAN YSIDRO ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 04/15/2024) |
Sample Information
| Sample Taken Date | 01/27/2025 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/28/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Lenton Form Savor Couplers |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Sairama | Last name of sampler or witnessed by | Jothiraj |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Creek Bridges | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Lenton | Intermediate Assembler or Fabricator | |
| Rebar Size | #5 | Coupler Model | Lenton Form Savor |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | M0276/245251 | Rebar Heat Number(s) | 4144473 |
| Rebar Size 2 | Coupler Unique ID | ST-17-05 |
Test Details
DIME Sample ID: 2025-01-27-7
DIME Test ID: 2025-01-27-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-02-03
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 01/29/2025
UTM: NA
Halo ID: 000
Temperature: 000 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 4144473 | 5 | 0.31 | 0.0078 | 28950 | 93387 | Atlas Technical Consultants | Miguel Baltazar |
| 2 | 2A | 4144473 | 5 | 0.31 | 000 | 28620 | 92323 | Atlas Technical Consultants | Miguel Baltazar |
| 3 | 3A | 4144473 | 5 | 0.31 | 000 | 28340 | 91419 | Atlas Technical Consultants | Miguel Baltazar |
| 4 | 4A | 4144473 | 5 | 0.31 | 000 | 28700 | 92581 | Atlas Technical Consultants | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/3/2025 ✔