Summary for Test 2024-12-11-55-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 995106
DEA: 072XA604
EFIS: 0723000080
DIST-CO-RTE-PM07-LA-2-65.2/66.4, 65.2/66.40000000000001
Award Date12/16/2022
Closeout Date09/25/2025
Work DescriptionRepair/reconstruct side slope at the erosion gullies, earthen berms along the shoulder, reconstruct existing MGS, place erosion control on the reconstructed side slopes
Location DescriptionNot set
QA Service Level1 (Verified on 08/30/2023)

Sample Information

Sample Taken Date12/11/2024 Sample Unique Key55
Date that the sample was received by the laboratory/organization performing the testing12/11/2024 Sample typeAcceptance
A brief description of the sample07-LA/Route 02 PM 65.3 The quantity of what the sample constitutes556 sy
From where was the sample collectedJob Site First name of sampler or witnessed byCaesar
Last name of sampler or witnessed byRamirez Title of samplerTransportation Engineer Civil
Telephone number of sampler(818) 974-8391 Laboratory sample identification24-3806
Linked DIME Sample ID The fabricator/manufacturer/facility nameContractor
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name07-LA/Route 02 PM 65.3
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleStructural Backfill
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedJob site
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-12-11-55
DIME Test ID: 2024-12-11-55-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-01-29

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Caesar Ramirez
Date of test: 12/11/2024
Gage No.: 31106
Test No.: 1
Nuclear By: Caesar Ramirez
Non-Bias Plan No.: 7
Depth: 11"
Material No.: Local Materials
Material Type: Structural Backfill
Impact By: Caesar Ramirez
Standard Count Density: 2161 g/cc
Count or Density 1: 2.31 g/cc
Count or Density 2: 2.34 g/cc
Count or Density 3: 2.27 g/cc
Standard Count Moisture: 621 g/cc
Moisture Count 1: 0.09 g/cc
Moisture Count 2: 0.14 g/cc
Moisture Count 3: 0.17 g/cc
Sum of Count or Density: 6.92 g/cc
Average of Count or Density: 2.31 g/cc
Sum of Moisture Count: 0.4 g/cc
Average of Moisture Count: 0.13 g/cc
Calculated Percent Relative Compaction: 98.3 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): Notified inspector Michael Maksimos of result

Test was verified on 1/29/2025 ✔