Summary for Test 2025-01-27-8-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date01/27/2025 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing01/27/2025 Sample typeQuality Assurance
A brief description of the sampleClass 2 AB used as Structure Backfill The quantity of what the sample constitutes67 SY
From where was the sample collectedJob Site First name of sampler or witnessed byNicholas
Last name of sampler or witnessed byHall Title of samplerMREA
Telephone number of sampler Laboratory sample identification25-6
Linked DIME Sample ID The fabricator/manufacturer/facility nameunknown
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameDavis Bent 3 footings
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedCollected from the compacted grade
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-01-27-8
DIME Test ID: 2025-01-27-8-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2025-01-28

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 01/27/2025
In-place wet density: 2.29
Highest adjust wet density: 2.39
% Moisture: 7.5 %
Optimum Moisture: 9.5 %
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/28/2025 ✔