Summary for Test 2024-12-30-14-4

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994267
DEA: 07326204
EFIS: 0716000113
DIST-CO-RTE-PM07-LA-39-17.8
Award Date11/23/2022
Closeout Date06/10/2025
Work DescriptionCONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date12/30/2024 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing12/31/2024 Sample typeAcceptance
A brief description of the sample4X8 PCC cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byGraham
Last name of sampler or witnessed byVelek Title of samplerAssistant Structure Representative
Telephone number of sampler Laboratory sample identification24-486
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Walnut
Transportation Laboratory (TL) Number07-326204-8 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected2 The batch plant ticket number from where the sample was collectedna
Concrete batch plantCemex Walnut The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-12-30-14
DIME Test ID: 2024-12-30-14-4
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-01-27

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 01/27/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 3.99 in
Maximum load on cylinder 1: 86659 lb
Maximum load on cylinder 2: 86827 lb
Maximum load on cylinder 3: 87934 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.5 in^2
Compressive strength of cylinder 1: 6894.1 psi
Compressive strength of cylinder 2: 6907.5 psi
Compressive strength of cylinder 3: 7034.7 psi
Compressive strength (to nearest 10 psi): 6950 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/27/2025 ✔