Summary for Test 2017-09-06-2-4
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 211513 DEA: 120M4904 EFIS: 1212000090 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-1.2/2.2 |
| Award Date | 09/20/2016 |
| Closeout Date | 01/09/2020 |
| Work Description | WIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS. |
| Location Description | ORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING |
| QA Service Level | 1 (Verified on 11/03/2016) |
Sample Information
| Sample Taken Date | 09/06/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/12/2017 | Sample type | Quality Assurance |
| A brief description of the sample | A 325 bolt | The quantity of what the sample constitutes | 7 lots |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Greg |
| Last name of sampler or witnessed by | Johnston | Title of sampler | |
| Telephone number of sampler | 9165247768 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Stinger Bridge Iron | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT008087, TT0087088, TT0087089, TT0087090, TT0087091, TT0087092, TT0087190, TT0087191, TT0087192, TT0087193, TT0087194, TT0087195 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 23286-6214073905 | |
| Washer Mfg. Lot Number(s) | 0416-213, 1116-407 | Bolt Specification | A325 |
| Bolt Length(s) | 3/4 x 2, 3/4 x 2 1/4, 7/8 x 2, 7/8 x 2 1/4, 7 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | Bolt Mfg. Lot Number | ||
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-09-06-2
DIME Test ID: 2017-09-06-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-09-22
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/14/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 9A | NA | 7/8\" | 65101 | 289.6 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 9/15/2017 ✔