Summary for Test 2024-08-08-130-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
| Award Date | 07/13/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
| Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 08/08/2024 | Sample Unique Key | 130 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2 - inch RHMA-O |
| The quantity of what the sample constitutes | 0-751 Tons | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | H | Last name of sampler or witnessed by | Sadie |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-08-08-130
DIME Test ID: 2024-08-08-130-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-01-27
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: LEO MENDOZA
Date of test: 01/27/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2039.4 g
Mass Loss: 187.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.05 %
General comments (publicly viewable) (Max 1000 characters): Sample # 1
0-750 Tons
Test was verified on 1/27/2025 ✔