Summary for Test 2024-12-10-83-4
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 212470 DEA: 044A1304 EFIS: 0400001106 COOP: 042718 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-101-18.5/18.5 |
| Award Date | 11/17/2023 |
| Closeout Date | Not set |
| Work Description | CONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY |
| Location Description | IN SONOMA COUNTY. |
| QA Service Level | 1 (Verified on 09/23/2019) |
Sample Information
| Sample Taken Date | 12/10/2024 | Sample Unique Key | 83 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/10/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 590CR2 |
| The quantity of what the sample constitutes | +40 cy | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Valdez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Supperior Supplies, Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 20-0304 | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-49-0004 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Conveyer Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | 590CR2 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-12-10-83
DIME Test ID: 2024-12-10-83-4
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-01-27
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 12/11/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.6
Sand reading (test 1): 3.8
Clay reading (test 2): 4.5
Sand reading (test 2): 3.6
Clay reading (test 3): 4.6
Sand reading (test 3): 3.6
Sand equivalent (test 1): 83
Sand equivalent (test 2): 80
Sand equivalent (test 3): 79
Sand equivalent before temperature correction: 81
Sand equivalent after temperature correction: 81
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/27/2025 ✔