Summary for Test 2025-01-11-2-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 1000578
DEA: 112N1704
EFIS: 1122000283
DIST-CO-RTE-PM11-SD-805-15.72-28.3
Award Date05/20/2024
Closeout Date06/09/2025
Work DescriptionBridge Preservation
Location DescriptionIn San Diego at various locations from Landis Street Overcrossing to Sorrento Valley Boulevard Undercrossing
QA Service Level1 (Verified on 09/03/2024)

Sample Information

Sample Taken Date01/11/2025 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2025
Sample typeQuality Assurance A brief description of the samplePSU
The quantity of what the sample constitutes3 bags From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMcCovy
Title of samplerTET Telephone number of sampler6193722435
Laboratory sample identification1601-PSU Linked DIME Sample ID2025-01-11-1
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number220817 Otay Val

Test Details

DIME Sample ID: 2025-01-11-2
DIME Test ID: 2025-01-11-2-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2025-01-23

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 2 Faced and Fine 1 Faced
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 01/23/2025
Mass of fractured, coarse, 2 faced particles tested: 1000 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 12 g
Mass of fractured, fine, 1 faced particles tested: 100 g
Mass of questionable, fine, 1 faced particles tested: 0 g
Mass of unfractured, fine, 1 faced particles tested: 0 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of questionable, fine, 1 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 99 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/23/2025