Summary for Test 2024-06-13-129-3

Test performed: ASTM D624-00r20

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/13/2024 Sample Unique Key129
Date that the sample was received by the laboratory/organization performing the testing12/02/2024 Sample typeQuality Assurance
A brief description of the sampleBearing Pad The quantity of what the sample constitutes3
From where was the sample collectedManufacturer First name of sampler or witnessed byRob
Last name of sampler or witnessed byAnderson Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameScougal Rubber
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)NA
Material/Compound/Elastomer ID33312 Samples Representing3
Description (size)NA Comments
Description (Number of Shims)0 Type of Bearing PadPlain
Description (Thickness of Shims)NA Manufacturer(s)Scougal Rubber
Batch NumberNA

Test Details

DIME Sample ID: 2024-06-13-129
DIME Test ID: 2024-06-13-129-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2025-01-22

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 01/22/2025
Humidity: 0 %
Temperature: 0 f
Sample 1 Median Thickness: 0.086 in
Sample 1 Tear Strength: 227 lb/in
Sample 2 Median Thickness: 0.074 in
Sample 2 Tear Strength: 223 lb/in
Sample 3 Median Thickness: 0.08 in
Sample 3 Tear Strength: 229 lb/in
UTM: NA
Median of the Tear Strength Values: 227 lb/in
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/22/2025