Summary for Test 2025-01-13-17-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994650
DEA: 070W4704
EFIS: 0722000073
DIST-CO-RTE-PM07-VEN-33,101-Var
Award Date05/25/2023
Closeout Date06/09/2025
Work DescriptionPLACE PIPELINER, CLEAN, INSPECT AND PREPARE CULVERTS.
Location DescriptionVENTURA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/18/2023)

Sample Information

Sample Taken Date01/13/2025 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2025
Sample typeAcceptance A brief description of the sample3/4" HMA-A 220200 SAT LTR
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byAvo Last name of sampler or witnessed byKarajian
Title of samplerMREA Telephone number of sampler
Laboratory sample identification25-005 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Saticoy Transportation Laboratory (TL) Number019357
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200 SAT LTR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-01-13-17
DIME Test ID: 2025-01-13-17-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-01-17

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 01/17/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4030.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 6120.7 g
Mass of HMA Sample prior to ignition: 2090.2 g
Mass Loss: 108.5 g
Mass of aggregate remaining after ignition: 1981.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.19 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/17/2025