Summary for Test 2024-12-19-11-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000805
DEA: 061G0904
EFIS: 0623000237
DIST-CO-RTE-PM06-FRE-41-R28.2
Award Date07/10/2023
Closeout DateNot set
Work DescriptionFre 41 Santa Ana Pump Replace. Remove existing pump, install temporary pump, and replace pump and associated appurtenances.
Location DescriptionFresno County along Route 41 near PM R28.2 at Pump Plant between Shaw Ave and Santa Ana Ave.
QA Service Level1 (Verified on 11/19/2024)

Sample Information

Sample Taken Date12/19/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/20/2024
Sample typeQuality Assurance A brief description of the samplePump Pedestal
The quantity of what the sample constitutes1CY From where was the sample collectedJob Site
First name of sampler or witnessed byAdam Last name of sampler or witnessed byMahmoud
Title of samplerASR Telephone number of sampler559-939-3921
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOutback Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier42-0381W
Structure nameSanta Ana Ave Pump Plant Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number63T1G01C
The truck number from where the sample was collected86 The batch plant ticket number from where the sample was collected173836
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-12-19-11
DIME Test ID: 2024-12-19-11-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-01-16

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 01/16/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 27780 lb
Maximum load on cylinder 2: 27220 lb
Maximum load on cylinder 3: 27990 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 6
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 2210.0 psi
Compressive strength of cylinder 2: 2165.5 psi
Compressive strength of cylinder 3: 2226.7 psi
Compressive strength (to nearest 10 psi): 2200 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/16/2025