Summary for Test 2024-12-18-26-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 212470
DEA: 044A1304
EFIS: 0400001106
COOP: 042718
DIST-CO-RTE-PM04-SON-101-18.5/18.5
Award Date11/17/2023
Closeout DateNot set
Work DescriptionCONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY
Location DescriptionIN SONOMA COUNTY.
QA Service Level1 (Verified on 09/23/2019)

Sample Information

Sample Taken Date12/18/2024 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing12/24/2024 Sample typeQuality Assurance
A brief description of the sampleConcrete for Abut 1, Stub Wall and Abut 1 RW The quantity of what the sample constitutes140 CY
From where was the sample collectedJob Site First name of sampler or witnessed byVenkat Varun
Last name of sampler or witnessed byGalla Title of samplerASR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSuperior Supplies
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number590CR2
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected307858
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedsample collected from concrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-12-18-26
DIME Test ID: 2024-12-18-26-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-01-15

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Nikhil Moon
Date of test: 01/15/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 75522 lb
Maximum load on cylinder 2: 69135 lb
Maximum load on cylinder 3: 71825 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 0.99
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 0.99
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5948.0 psi
Compressive strength of cylinder 2: 5500.0 psi
Compressive strength of cylinder 3: 5656.9 psi
Compressive strength (to nearest 10 psi): 5700 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/15/2025 ✔