Summary for Test 2025-01-09-25-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994191
DEA: 081G8304
EFIS: 0816000079
DIST-CO-RTE-PM08-SBD-40-R100.8/R101.8
Award Date02/07/2023
Closeout Date08/29/2025
Work DescriptionHMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW.
Location DescriptionSAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE
QA Service Level1 (Verified on 03/30/2023)

Sample Information

Sample Taken Date01/09/2025 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2025
Sample typeAcceptance A brief description of the sample3/4'' combined HMA Agg.
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byRuvalcaba
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Jobsite
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number30054-R25 LSM Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-01-09-25
DIME Test ID: 2025-01-09-25-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-01-14

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Francisco Ruvalcaba
Date of test: 01/10/2025
Cumulative Percent Passing
100 %
100 %
100 %
93 %
81 %
68 %
51 %
42 %
33 %
22 %
12 %
6 %
3.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/14/2025