Summary for Test 2024-12-17-49-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 994650
DEA: 070W4704
EFIS: 0722000073
DIST-CO-RTE-PM07-VEN-33,101-Var
Award Date05/25/2023
Closeout Date06/09/2025
Work DescriptionPLACE PIPELINER, CLEAN, INSPECT AND PREPARE CULVERTS.
Location DescriptionVENTURA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/18/2023)

Sample Information

Sample Taken Date12/17/2024 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing12/18/2024 Sample typeAcceptance
A brief description of the sampleConcrete Test Samples The quantity of what the sample constitutes10CY
From where was the sample collectedJob Site First name of sampler or witnessed byChad
Last name of sampler or witnessed byChotibhongs Title of samplerMREA
Telephone number of sampler2134076963 Laboratory sample identification25-0003
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociate Ready mixed Concrete
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSL705SC30
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected7248494
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheel Barrow from Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-12-17-49
DIME Test ID: 2024-12-17-49-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-01-14

Test Results


Number of specimens: 2
Input Type: Calculated
Tester's full name: Chad Chotibhongs
Date of test: 01/14/2025
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): Type 5
Break Description of Cylinder 2 (if not 'cone'): Type 5
Average Compressive Strength (to nearest 10): 6140 lb/in^2
Compressive Strength of Cylinder 1: 6390.34 lb/in^2
Compressive Strength of Cylinder 2: 5884.01 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/14/2025 ✔