Summary for Test 2024-12-10-29-7

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 1000293
DEA: 041X3204
EFIS: 0424000308
DIST-CO-RTE-PM04-SON-1-38.58
Award Date02/22/2024
Closeout DateNot set
Work DescriptionConstruct soldier pile wall, repair east side slide w/ concrete canvass, reconstruct roadway, reconstruct metal beam guardrail, pavement delineation, install structural shotcrete, stain concrete/shotcrete, install cable railing, and install erosions contr
Location DescriptionOcean Cove (North) Emergency Wall at Walsh Landing
QA Service Level1 (Verified on 04/23/2024)

Sample Information

Sample Taken Date12/10/2024 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/18/2024
Sample typeQuality Assurance A brief description of the sampleCore sample from test panel
The quantity of what the sample constitutes24 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRichard Last name of sampler or witnessed byJones
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCanyon Rock Forestville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier20-0116
Structure nameOcean Cove Emergency Wall Bid ItemNot set

Material Information

Material TypeConcrete Core Detail descriptionShotcrete Wall Test Panel
Structure namesOcean Cove Emergency Wall Type of materialShotcrete Mix 80201503

Test Details

DIME Sample ID: 2024-12-10-29
DIME Test ID: 2024-12-10-29-7
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-01-23

Test Results


Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 01/07/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 2.42 in
Average diameter of cylinder 2: 2.43 in
Average diameter of cylinder 3: 2.42 in
Average diameter of cylinder 4: 2.42 in
Maximum load on cylinder 1: 27150 lb
Maximum load on cylinder 2: 27580 lb
Maximum load on cylinder 3: 27450 lb
Maximum load on cylinder 4: 28230 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 3
Type of fracture pattern of cylinder 4: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 4.6 in^2
Cross sectional area of cylinder 2: 4.6 in^2
Cross sectional area of cylinder 3: 4.6 in^2
Cross sectional area of cylinder 4: 4.6 in^2
Compressive strength (to nearest 10 psi): 5990 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/23/2025