Summary for Test 2024-12-17-46-6
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1000187 DEA: 112N1674 EFIS: 1122000280 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-86-R34.8/64.1 |
| Award Date | 06/04/2024 |
| Closeout Date | 06/09/2025 |
| Work Description | POLYESTER CONCRETE OVERLAY, APPLY METHACRYLATE,& JOINT SEALS. |
| Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM TRIFOLIUM CANAL BRIDGE (58-0017) TO GODETIA DITCH BRIDGE (58-0067) |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 12/17/2024 | Sample Unique Key | 46 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/20/2024 | Sample type | Quality Assurance |
| A brief description of the sample | PSU | The quantity of what the sample constitutes | 12 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Derrick |
| Last name of sampler or witnessed by | McCovy | Title of sampler | TET |
| Telephone number of sampler | 6193722435 | Laboratory sample identification | 1501-PSU |
| Linked DIME Sample ID | 2024-12-17-47 | The fabricator/manufacturer/facility name | API Gateway |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 39 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-12-17-46
DIME Test ID: 2024-12-17-46-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-01-15
Test Results
Specified number of passes at 12.7 mm: 20000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 12/24/2024
Test Temperature: 131 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 2.54 mm
Maximum impression at 5000 passes (right wheel): 1.85 mm
Average impression at 5000 passes (left/right avg): 2.2 mm
Maximum impression at 10000 passes (left wheel): 5.08 mm
Maximum impression at 10000 passes (right wheel): 3.7 mm
Average impression at 10000 passes (left/right avg): 4.39 mm
Maximum impression at 15000 passes (left wheel): 7.62 mm
Maximum impression at 15000 passes (right wheel): 5.55 mm
Average impression at 15000 passes (left/right avg): 6.59 mm
Maximum impression at 20000 passes (left wheel): 10.14 mm
Maximum impression at 20000 passes (right wheel): 7.38 mm
Average impression at 20000 passes (left/right avg): 8.76 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies Target < 12.7 mm Tested 8.79 mm
Test was verified on 1/15/2025 ✔