Summary for Test 2024-12-04-49-7
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 1000178 DEA: 051P7304 EFIS: 0522000101 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-9-7.5/10.2 |
| Award Date | 05/29/2024 |
| Closeout Date | 09/02/2025 |
| Work Description | COLD PLANE AC PAVEMENT, PLACE RHMA-G, AND RECONSTRUCT CURB RAMPS. |
| Location Description | SANTA CRUZ COUNTY IN AND NEAR BEN LOMOND FROM 0.1 MILE NORTH OF LAZY WOODS ROAD TO 0.1 MILE NORTH OF CALIFORNIA DRIVE |
| QA Service Level | 1 (Verified on 03/25/2024) |
Sample Information
| Sample Taken Date | 12/04/2024 | Sample Unique Key | 49 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/12/2024 |
| Sample type | Verification | A brief description of the sample | SS1 |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Yantsey | Last name of sampler or witnessed by | Chang |
| Title of sampler | Assistant RE | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite | Transportation Laboratory (TL) Number | 00000 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1 |
|---|---|---|---|
| Lot Number | 1 | Sub Lot | 1 |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2024-12-04-49
DIME Test ID: 2024-12-04-49-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphaltic Emulsion)
Test Release Date: 2025-02-12
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Was test performed on residue from distillation or evaporation?: Evaporation
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Ductility of test #1 (D1): 430 mm
Ductility of sample: 430 mm
General comments (publicly viewable) (Max 1000 characters): Information Only-sample was tested beyond 14 days. Test result complies with specification.
Test was verified on 2/12/2025 ✔