Summary for Test 2017-09-07-1-2
Test performed: ASTM A775-07b-re14Project Information
| Project Identifiers | Project ID: 211394 DEA: 100G8204 EFIS: 1013000073 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-132-0.4/7.1 |
| Award Date | 07/20/2016 |
| Closeout Date | 01/04/2021 |
| Work Description | REPAIR PAVEMENT AND INSTALL ITS ELEMENTS. |
| Location Description | SAN JOAQUIN COUNTY NEAR VERNALIS FROM 0.4 MILE EAST OF ROUTE 580 TO STANISLAUS COUNTY LINE |
| QA Service Level | 1 (Verified on 09/23/2016) |
Sample Information
| Sample Taken Date | 09/07/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/08/2017 | Sample type | Quality Assurance |
| A brief description of the sample | A775 Epoxy Coated Dowel Baskets | The quantity of what the sample constitutes | 1 Truck Load |
| From where was the sample collected | Source | First name of sampler or witnessed by | Rob |
| Last name of sampler or witnessed by | Ramos | Title of sampler | QA |
| Telephone number of sampler | 916-996-2658 | Laboratory sample identification | Riverbank, CA |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Dayton Superior |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | S08-034-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Dowels | Dowel Metal Heat Number | SE17102265 PL17102440 |
|---|---|---|---|
| Dowel Epoxy Batch Number | 7396024285 7196023954 | Dowel Coating Specification | ASTM A775 |
| Dowel Size | 1.25 in | Dowel Coating Color | Green |
| Dowel Manufacturer | Unknown | Dowel Coater | Dayton Superior |
| Release Number | 1349571-5 | Quality Assurance Code | Unknown |
| Rebar Size (#) | Unknown |
Test Details
DIME Sample ID: 2017-09-07-1
DIME Test ID: 2017-09-07-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2017-09-19
Test Results
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 09/12/2017
Total Number of Holiday: 0
Total Length: 3 ft
Holidays Per Linear Foot of Bar: 0 holiday pe
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: NA
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2017 ✔