Summary for Test 2024-10-01-135-5
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/01/2024 | Sample Unique Key | 135 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2024 |
| Sample type | Verification | A brief description of the sample | Tank 40 |
| The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Keven | Last name of sampler or witnessed by | Heitschmidt |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | PG641610124KF40 | Linked DIME Sample ID | 2024-10-01-123 |
| The fabricator/manufacturer/facility name | Klamath Falls, OR | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Albina Asphalt (Klamath Falls Plant) - Klamath Falls OR | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-10-01-135
DIME Test ID: 2024-10-01-135-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2025-01-22
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/28/2024
Ductility of test #1 (D1): 100 cm
Ductility of sample: 100 cm
General comments (publicly viewable) (Max 1000 characters): DUCT
Test was verified on 1/22/2025 ✔