Summary for Test 2024-12-14-8-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 994582
DEA: 073203U4
EFIS: 0722000071
DIST-CO-RTE-PM07-LA-91,605-R16.6/R16.8,R0.0/R10.4
Award Date06/20/2023
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT AND HIGH FRICTION SURFACE TREATMENT.
Location DescriptionLOS ANGELES COUNTY ON ROUTE 605 FROM 0.2 MILE NORTH OF KATELLA AVENUE UNDECROSSING TO 0.1 MILE NORTH OF TELEGRAPH ROAD UNDERCROSSING AND ON ROUTE 91 FROM 0.4 MILE WEST OF ROUTE 605 UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 605 UNDERCROSSING
QA Service Level1 (Verified on 07/12/2023)

Sample Information

Sample Taken Date12/14/2024 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing12/14/2024 Sample typeQuality Assurance
A brief description of the sample3 - 6X6X21 Rapid Set Concrete Beams The quantity of what the sample constitutes10 CY
From where was the sample collectedJob Site First name of sampler or witnessed byDominic
Last name of sampler or witnessed byMontemayor Title of samplerMaterials Tester
Telephone number of sampler9517643140 Laboratory sample identification24-3876
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberHE4X12BM
The truck number from where the sample was collectedTruck 82 The batch plant ticket number from where the sample was collectedLoad 1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-12-14-8
DIME Test ID: 2024-12-14-8-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-01-08

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Dominic Montemayor
Date of test: 01/08/2025
Identification number: 24-3877
Width of specimen: 5.9375 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.25 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 860 psi
Maximum recording 2: 835 psi
Maximum recording 3: 795 psi
Correction Factor: 0.93
Correction Factor 2: 0.97
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 840 psi
Modulus of rupture 2: 850 psi
Modulus of rupture 3: 830 psi
Modulus of rupture average: 840 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/8/2025 ✔