Summary for Test 2024-10-16-43-7

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/23/2021
Closeout DateNot set
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date10/16/2024 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2024
Sample typeAcceptance A brief description of the samplePG 64-16
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byALBERTO Last name of sampler or witnessed byLopez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refining Co Inc Transportation Laboratory (TL) Number771955
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-10-16-43
DIME Test ID: 2024-10-16-43-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-01-27

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and kilopascals
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/24/2024
Observed Flash Point: 308 C
Ambient Barometric Pressure: 103 kP
Cleveland Open-Cup Flash Point in Celsius: 308 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/27/2025