Summary for Test 2024-10-09-71-9
Test performed: AASHTO T316-17Project Information
| Project Identifiers | Project ID: 995036 DEA: 061E7704 EFIS: 0622000080 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-204-2.1/4.6 |
| Award Date | 04/18/2024 |
| Closeout Date | 05/09/2025 |
| Work Description | TRANSPORTATION ART, TRAFFIC STRIPE, IRRIGATION AND PLANTING WORK. |
| Location Description | KERN COUNTY IN BAKERSFIELD FROM BRUNDAGE LANE TO M STREET |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 10/09/2024 | Sample Unique Key | 71 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/15/2024 |
| Sample type | Acceptance | A brief description of the sample | PG 58-16 |
| The quantity of what the sample constitutes | 1 qt can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Sam | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite San Joaquin | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 755194 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | Granite Solari | |
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-10-09-71
DIME Test ID: 2024-10-09-71-9
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-01-27
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: 0.66 in
Torque: 9.7 %
Viscosity reading #1 (A) : 0.244 Pa-s
Viscosity reading #2 (B) : 0.244 Pa-s
Viscosity reading #3 (C): 0.244 Pa-s
Average viscosity: 0.244 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOSITY @ 135C
Test was verified on 1/27/2025 ✔