Summary for Test 2024-10-08-98-1

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 995005
DEA: 060X7004
EFIS: 0619000009
DIST-CO-RTE-PM06-TUL-63-5.8/L8.0
Award Date09/21/2023
Closeout DateNot set
Work DescriptionCOLD PLANE PAVEMENT, PLACE RHMA-G, MODIFY LIGHTING AND SIGNAL SYSTEM.
Location DescriptionTULARE COUNTY IN VISALIA FROM 0.2 MILE SOUTH OF CALDWELL AVENUE TO ROUTE 63/198 SEPARATION
QA Service Level1 (Verified on 07/27/2023)

Sample Information

Sample Taken Date10/08/2024 Sample Unique Key98
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2024
Sample typeQuality Assurance A brief description of the samplePG 70-10
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byCesar Last name of sampler or witnessed byMandujano
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina Chowchilla Transportation Laboratory (TL) Number771959
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Chowchilla CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-10-08-98
DIME Test ID: 2024-10-08-98-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-01-23

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Phase Angle (δ) (for the 10 cycles): 0.0 degree
Dynamic Shear, G*/sin(δ): 1.31 kPa
General comments (publicly viewable) (Max 1000 characters): Original

Test was verified on 1/23/2025