Summary for Test 2024-10-06-24-7
Test performed: AASHTO T48-18Project Information
| Project Identifiers | Project ID: 995005 DEA: 060X7004 EFIS: 0619000009 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-63-5.8/L8.0 |
| Award Date | 09/21/2023 |
| Closeout Date | Not set |
| Work Description | COLD PLANE PAVEMENT, PLACE RHMA-G, MODIFY LIGHTING AND SIGNAL SYSTEM. |
| Location Description | TULARE COUNTY IN VISALIA FROM 0.2 MILE SOUTH OF CALDWELL AVENUE TO ROUTE 63/198 SEPARATION |
| QA Service Level | 1 (Verified on 07/27/2023) |
Sample Information
| Sample Taken Date | 10/06/2024 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2024 |
| Sample type | Quality Assurance | A brief description of the sample | PG 70-10 |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Cesar | Last name of sampler or witnessed by | Mandujano |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Albina Chowchilla | Transportation Laboratory (TL) Number | 771957 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-10-06-24
DIME Test ID: 2024-10-06-24-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-01-23
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and kilopascals
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/24/2024
Observed Flash Point: 319 C
Ambient Barometric Pressure: 102 kP
Cleveland Open-Cup Flash Point in Celsius: 319 C
General comments (publicly viewable) (Max 1000 characters): FLASH POINT
Test was verified on 1/23/2025 ✔