Summary for Test 2024-12-02-24-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 994331 DEA: 11430254 EFIS: 1118000079 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-52-5.1/9.0 |
| Award Date | 12/21/2023 |
| Closeout Date | Not set |
| Work Description | CONST AUX LANE, COMPACTION GROUTING, RHMA, LANDSCAPE, & ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE WEST OF CONVOY STREET OVERCROSSING TO 0.3 MILE EAST OF SANTO ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/05/2024) |
Sample Information
| Sample Taken Date | 12/02/2024 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/16/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Plant Sample |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derrick | Last name of sampler or witnessed by | McCovy |
| Title of sampler | TET | Telephone number of sampler | 6193722435 |
| Laboratory sample identification | 0812-A | Linked DIME Sample ID | 2024-12-02-23 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0036 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 23417005SR MM |
Test Details
DIME Sample ID: 2024-12-02-24
DIME Test ID: 2024-12-02-24-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2025-01-17
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 01/17/2025
Clay Level (Test 1): 5.3
Sand Level (Test 1): 4.4
Clay Level (Test 2): 5.2
Sand Level (Test 2): 4.2
Clay Level (Test 3): 5.6
Sand Level (Test 3): 4.5
Sand Equivalent (Test 1): 83
Sand Equivalent (Test 2): 81
Sand Equivalent (Test 3): 81
Sand Equivalent: 82
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/17/2025 ✔
