Summary for Test 2024-11-19-58-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 994226
DEA: 042K7004
EFIS: 0417000010
COOP: 042895
DIST-CO-RTE-PM04-ALA-880-R0.0/11.8
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE)
Location DescriptionALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date11/19/2024 Sample Unique Key58
Date that the sample was received by the laboratory/organization performing the testing11/20/2024 Sample typeAnnual Source Testing
A brief description of the sampleFine Aggregate Sand The quantity of what the sample constitutesAmple
From where was the sample collectedSource First name of sampler or witnessed byCurtis
Last name of sampler or witnessed byGilbert Title of samplerPlant QC
Telephone number of sampler Laboratory sample identificationHW-111924-ST
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Pleasanton
Transportation Laboratory (TL) NumberC689530 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010::CALMAT/PLEASANTON
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-11-19-58
DIME Test ID: 2024-11-19-58-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-01-03

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Leonardo Mendoza
Date of test: 01/03/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.2
Sand reading (test 1): 3.9
Sand equivalent (test 1): 75
Sand equivalent before temperature correction: 75
Sand equivalent after temperature correction: 75
General comments (publicly viewable) (Max 1000 characters): Test passed

Test was verified on 1/3/2025 ✔