Summary for Test 2024-10-17-72-14
Test performed: AASHTO T48-18Project Information
| Project Identifiers | Project ID: 995524 DEA: 021H3604 EFIS: 0216000040 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96-76.8/78.0 |
| Award Date | 03/22/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK |
| QA Service Level | 1 (Verified on 12/27/2023) |
Sample Information
| Sample Taken Date | 10/17/2024 | Sample Unique Key | 72 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/12/2024 |
| Sample type | Quality Assurance | A brief description of the sample | PG 58-34 M |
| The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Tullis Redding | Transportation Laboratory (TL) Number | 851391 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
|---|---|---|---|
| Modified | Yes | Lot number | 1 |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-10-17-72
DIME Test ID: 2024-10-17-72-14
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-01-15
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and kilopascals
Input Type: Measured
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Observed Flash Point: 292 C
Ambient Barometric Pressure: 103 kP
Cleveland Open-Cup Flash Point in Celsius: 292 C
General comments (publicly viewable) (Max 1000 characters): FLASHPOINT
Test was verified on 1/15/2025 ✔