Summary for Test 2024-11-04-64-5

Test performed: ASTM D217-16

Project Information

Project IdentifiersProject ID: 1000799
DEA: 010H6504
EFIS: 0117000246
DIST-CO-RTE-PM01-HUM-101-55.9/R136.4
Award Date07/25/2025
Closeout DateNot set
Work DescriptionDRAINAGE SYSTEM RESTORATION
Location DescriptionHUMBOLDT COUNTY NEAR ALTON FROM 0.3 MILE SOUTH OF VAN DUZEN RIVER BRIDGE 4-17 TO DEL NORTE COUNTY LINE
QA Service Level1 (Verified on 11/15/2024)

Sample Information

Sample Taken Date11/04/2024 Sample Unique Key64
Date that the sample was received by the laboratory/organization performing the testing11/13/2024 Sample typeAcceptance
A brief description of the samplerubber The quantity of what the sample constitutesi can of rubber
From where was the sample collectedSource First name of sampler or witnessed byt
Last name of sampler or witnessed byThorpe Title of samplertester
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero-Benicia Asphalt Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Formc972441
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2024-11-04-64
DIME Test ID: 2024-11-04-64-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2024-12-27

Test Results


Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Unworked Penetration, Test 1: 29.6 0.1 mm
Unworked Penetration, Test 2: 31 0.1 mm
Unworked Penetration, Test 3: 31.4 0.1 mm
Unworked Penetration: 31 0.1 mm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/27/2024 ✔