Summary for Test 2024-12-03-26-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994875
DEA: 101F1804
EFIS: 1016000077
DIST-CO-RTE-PM10-SJ-4-R16.0/R19.4
Award Date09/20/2023
Closeout DateNot set
Work DescriptionBRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION
QA Service Level1 (Verified on 06/14/2023)

Sample Information

Sample Taken Date12/03/2024 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/05/2024
Sample typeQuality Assurance A brief description of the sampleLenton Coupler
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Lenton Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelA2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A232296 M0204 Rebar Heat Number(s)9004173
Rebar Size 2 Coupler Unique IDST-17-01

Test Details

DIME Sample ID: 2024-12-03-26
DIME Test ID: 2024-12-03-26-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2024-12-27

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/24/2024
UTM: NA
Halo ID: 000
Temperature: 000 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11AA23229680.790.00037154090557Atlas Technical ConsultantsAtlas Technical Consultants
22AA23229680.790007076089570Atlas Technical ConsultantsAtlas Technical Consultants
33AA23229680.790007110090000Atlas Technical ConsultantsAtlas Technical Consultants
44AA23229680.790007090089747Atlas Technical ConsultantsAtlas Technical Consultants

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/27/2024