Summary for Test 2024-10-30-72-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date10/30/2024 Sample Unique Key72
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/31/2024
Sample typeAcceptance A brief description of the sample1/2" WMA-A 320200W SVA VLO
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byChristian Last name of sampler or witnessed byGonzalez
Title of samplerVULCAN QC Telephone number of sampler
Laboratory sample identification24-387 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Sun Valley Transportation Laboratory (TL) Number019589
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320200W SVA VLO
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-30-72
DIME Test ID: 2024-10-30-72-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-12-20

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 11/18/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7359.3 grams
Mass of oven-dry sample in air for Sample 1: 1544.2 grams
Mass of container filled with the sample and water for Sample 1: 8288.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.511
Theoretical maximum density at 25°C (77°F): 156.3 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/20/2024