Summary for Test 2024-11-05-74-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date11/05/2024 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2024
Sample typeQuality Assurance A brief description of the samplePlant Sample
The quantity of what the sample constitutes3 bags From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMcCovy
Title of samplerTET Telephone number of sampler6193722435
Laboratory sample identification65118-S Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number6038801

Test Details

DIME Sample ID: 2024-11-05-74
DIME Test ID: 2024-11-05-74-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-12-23

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 12/20/2024
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
525.3 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
8.4 grams98 %
525.3 grams
6.3 grams97 %
181.6 grams64 %
310.9 grams40 %
416.1 grams20 %
467.3 grams11 %
504.1 grams4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/23/2024