Summary for Test 2024-12-11-36-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 209698 DEA: 072332E4 EFIS: 0700000391 COOP: 0705187 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-I-5-45.4/54 |
| Award Date | 07/01/2021 |
| Closeout Date | Not set |
| Work Description | Addition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley |
| Location Description | The I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd. |
| QA Service Level | 2 (Verified on 02/03/2021) |
Sample Information
| Sample Taken Date | 12/11/2024 | Sample Unique Key | 36 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2024 |
| Sample type | Acceptance | A brief description of the sample | 3/4" wma-a 220200W SVA VLO |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cesar | Last name of sampler or witnessed by | Gomez |
| Title of sampler | Vulcan QC | Telephone number of sampler | |
| Laboratory sample identification | 24-475 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 019718 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200W SVA VLO | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-12-11-36
DIME Test ID: 2024-12-11-36-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-19
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 12/19/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4012.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6057.6 g
Mass of HMA Sample prior to ignition: 2044.7 g
Mass Loss: 99.0 g
Mass of aggregate remaining after ignition: 1945.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.84 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/19/2024 ✔