Summary for Test 2024-12-05-48-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/05/2024 | Sample Unique Key | 48 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/06/2024 | Sample type | Verification |
| A brief description of the sample | JMF-PP | The quantity of what the sample constitutes | 24 BOXES RWMA |
| From where was the sample collected | Source | First name of sampler or witnessed by | Derrick |
| Last name of sampler or witnessed by | McCovy | Title of sampler | |
| Telephone number of sampler | 6193722435 | Laboratory sample identification | 1203-JMF |
| Linked DIME Sample ID | 2024-12-05-49 | The fabricator/manufacturer/facility name | Vulcan Otay |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Not Applicable |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 326122 Otay SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-12-05-48
DIME Test ID: 2024-12-05-48-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-12-19
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?: Lab compacted
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 12/17/2024
| 1 | 2 | 3 | ||||
|---|---|---|---|---|---|---|
| 2.322 | 2.324 | 2.328 | ||||
| 2.419 | ||||||
4.0 % | 3.9 % | 3.8 % | ||||
3.9 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Complies Target 4.0% Air Voids Tested an Avg of 3.9% Air Voids
Test was verified on 12/19/2024 ✔