Summary for Test 2024-09-24-46-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 993387
DEA: 07323404
EFIS: 0716000064
DIST-CO-RTE-PM07-LA-5-R59.5/R67.9
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date09/24/2024 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/26/2024
Sample typeProduction Start-Up A brief description of the sample3/4" HMA A SP R25 .75% LAS
The quantity of what the sample constitutes20 BX HMA 4 BG CMB AGG 2 BGS RAP 4 QTS PG58-16 1 QT LAS From where was the sample collectedManufacturer
First name of sampler or witnessed byCHRIST Last name of sampler or witnessed byVULCAN - QC
Title of sampler Telephone number of sampler
Laboratory sample identification0498A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200M IRW SJR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-24-46
DIME Test ID: 2024-09-24-46-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2024-12-17

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Marta Landaverde
Date of test: 10/01/2024
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Treated

199 psi

256 psi

78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/17/2024