Summary for Test 2024-12-05-48-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/05/2024 | Sample Unique Key | 48 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/06/2024 |
| Sample type | Verification | A brief description of the sample | JMF-PP |
| The quantity of what the sample constitutes | 24 BOXES RWMA | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derrick | Last name of sampler or witnessed by | McCovy |
| Title of sampler | Telephone number of sampler | 6193722435 | |
| Laboratory sample identification | 1203-JMF | Linked DIME Sample ID | 2024-12-05-49 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Not Applicable |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 326122 Otay SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-12-05-48
DIME Test ID: 2024-12-05-48-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-19
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 12/17/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4010.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5558.9 g
Mass of HMA Sample prior to ignition: 1548.3 g
Mass Loss: 137.1 g
Mass of aggregate remaining after ignition: 1411.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.80 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.05 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 8.70% Tested 8.05%
Test was verified on 12/19/2024 ✔