Summary for Test 2024-10-28-63-5
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994246 DEA: 051H6904 EFIS: 0516000140 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-101-R91.3/98.8,100.3/101.3 |
| Award Date | 12/27/2022 |
| Closeout Date | Not set |
| Work Description | PLACE RHMA, INSTALL CONCRETE BARRIER AND DRAINAGE SYSTEMS. |
| Location Description | MONTEREY COUNTY AT AND NEAR PRUNEDALE AND SALINAS FROM 0.3 MILE NORTH OF BORONDA ROAD OVERCROSSING TO 0.4 MILE NORTH OF CRAZY HORSE CANYON ROAD OVERCROSSING AND FROM 0.9 MILE NORTH OF CRAZY HORSE CANYON ROAD OVERCROSSING TO SAN JUAN ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/19/2022) |
Sample Information
| Sample Taken Date | 10/28/2024 | Sample Unique Key | 63 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2024 |
| Sample type | Quality Control | A brief description of the sample | Concrete |
| The quantity of what the sample constitutes | 100 cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Hugo | Last name of sampler or witnessed by | Serrano |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Rock | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 577720 |
|---|---|---|---|
| The truck number from where the sample was collected | 2371 | The batch plant ticket number from where the sample was collected | 200810 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | concrete truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-28-63
DIME Test ID: 2024-10-28-63-5
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-12-17
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Hugo Serrano
Date of test: 10/28/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 181610 lb
Maximum load on cylinder 2: 178270 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6370 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/17/2024 ✔