Summary for Test 2024-10-24-91-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
| Award Date | 07/13/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
| Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 10/24/2024 | Sample Unique Key | 91 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/08/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 RHMA-G | The quantity of what the sample constitutes | 0-750 Tons |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Magana |
| Last name of sampler or witnessed by | Luis | Title of sampler | |
| Telephone number of sampler | 2092250104 | Laboratory sample identification | HW-090924-ACSE1 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Materials-Pleasanton | |
| Transportation Laboratory (TL) Number | C690435 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 14 | HMA Mix Number | D04 JMF 24 035 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-10-24-91
DIME Test ID: 2024-10-24-91-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-16
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Conception
Date of test: 10/24/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2090.9 g
Mass Loss: 174.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.01 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.17 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2024 ✔