Summary for Test 2024-12-05-35-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214486
DEA: 080K1224
EFIS: 0815000244
DIST-CO-RTE-PM08-SBD-15-R28.6/37.5
Award Date09/24/2021
Closeout Date11/03/2025
Work DescriptionREHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date12/05/2024 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2024
Sample typeAcceptance A brief description of the sample3/4" HMA A SP R25 1.0% LSM
The quantity of what the sample constitutes3 BOXES OF HMA, 1 QT OF PG58-34M From where was the sample collectedManufacturer
First name of sampler or witnessed byCIZITERE Last name of sampler or witnessed byO
Title of sampler Telephone number of sampler
Laboratory sample identification0663A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number87 HMA Mix Number300154 R25 LSM
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-12-05-35
DIME Test ID: 2024-12-05-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-16

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 12/10/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2178.9 g
Mass Loss: 116.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.55 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.65 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/16/2024