Summary for Test 2024-12-09-9-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000696 DEA: 061H3304 EFIS: 0625000036 |
|---|---|
| DIST-CO-RTE-PM | 06--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/14/2024) |
Sample Information
| Sample Taken Date | 12/09/2024 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 12/10/2024 |
| Sample type | Quality Assurance | A brief description of the sample | #11 D250L Coupler |
| The quantity of what the sample constitutes | 1 lot | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Fares | Last name of sampler or witnessed by | Thwabah |
| Title of sampler | Assistant Structure Representative | Telephone number of sampler | 559-287-5457 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 42-0171 | |
| Structure name | Toulumne Street OC | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Nucor Steel |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | |
| Rebar Size | #11 | Coupler Model | D250L |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 207506 4000016126 4000016130 | Rebar Heat Number(s) | 3500039578 |
| Rebar Size 2 | Coupler Unique ID | SL-17-06 |
Test Details
DIME Sample ID: 2024-12-09-9
DIME Test ID: 2024-12-09-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)
Test Release Date: 2024-12-14
Test Results
Necking Test Option: Necking Test Option I
Shape of the Sample: Straight Sample
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/13/2024
Sample 1 Visible Necking?: Yes
Sample 1 Location of Fracture?: Rebar
Sample 2 Visible Necking?: Yes
Sample 2 Location of Fracture?: Rebar
Sample 3 Visible Necking?: Yes
Sample 3 Location of Fracture?: Rebar
Sample 4 Visible Necking?: Yes
Sample 4 Location of Fracture?: Rebar
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants
Test was verified on 12/14/2024 ✔