Summary for Test 2024-11-23-1-6

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 993432
DEA: 11423804
EFIS: 1116000061
DIST-CO-RTE-PM11-SD-94,125-R9.8/R10.6,12.9/22.3
Award Date04/27/2022
Closeout Date06/09/2025
Work DescriptionCONSTRUCT INDIVIDUAL SLAB, HMA, RHMA, MODIFY LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY ON ROUTE 94 FROM E94/N125 SEPARATION IN LEMON GROVE TO 0.1 MILE EAST OF SPRING STREET UNDERCROSSING IN LA MESA AND ON ROUTE 125 FROM 0.6 MILE SOUTH OF SPRING STREET UNDERCROSSING NEAR LA MESA TO MISSION GORGE ROAD IN SANTEE
QA Service Level1 (Verified on 12/20/2021)

Sample Information

Sample Taken Date11/23/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/05/2024
Sample typeQuality Assurance A brief description of the sampleRHMA-G
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMcCovy
Title of sampler Telephone number of sampler6193722435
Laboratory sample identification07135-PSU Linked DIME Sample ID2024-11-23-2
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21218080SR MM
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-11-23-1
DIME Test ID: 2024-11-23-1-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-12-19

Test Results


Specified number of passes at 12.7 mm: 20000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 12/12/2024
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 1.22 mm
Maximum impression at 5000 passes (right wheel): 1.78 mm
Average impression at 5000 passes (left/right avg): 1.5 mm
Maximum impression at 10000 passes (left wheel): 1.79 mm
Maximum impression at 10000 passes (right wheel): 2.96 mm
Average impression at 10000 passes (left/right avg): 2.38 mm
Maximum impression at 15000 passes (left wheel): 2.2 mm
Maximum impression at 15000 passes (right wheel): 4.11 mm
Average impression at 15000 passes (left/right avg): 3.16 mm
Maximum impression at 20000 passes (left wheel): 2.57 mm
Maximum impression at 20000 passes (right wheel): 5.09 mm
Average impression at 20000 passes (left/right avg): 3.83 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies Target 12.7mm Tested an Avg of 3.82 mm

Test was verified on 12/19/2024