Summary for Test 2024-09-20-103-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993333 DEA: 04264724 EFIS: 0419000068 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-R20.8/27.1 |
Award Date | 04/26/2022 |
Closeout Date | Not set |
Work Description | CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 09/20/2024 | Sample Unique Key | 103 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/23/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-SP Type A |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cody | Last name of sampler or witnessed by | Cordero |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | PET-24-465 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Dutra San Rafael | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 12 |
Sublot number | 12 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-09-20-103
DIME Test ID: 2024-09-20-103-1
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-12
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 09/24/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3082.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 5117.1 g
Mass of HMA Sample prior to ignition: 2034.9 g
Mass Loss: 139.6 g
Mass of aggregate remaining after ignition: 1895.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.72 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/12/2024 ✔