Summary for Test 2024-11-08-57-3
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 11/08/2024 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/05/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 3 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Pete | Last name of sampler or witnessed by | Liloyan |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex Fairfield | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | OS 83-1 | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1613820 |
|---|---|---|---|
| The truck number from where the sample was collected | 10077241 | The batch plant ticket number from where the sample was collected | 31409804 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Back of truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-11-08-57
DIME Test ID: 2024-11-08-57-3
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-12-10
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Nikhil Moon
Date of test: 12/06/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 87990 lb
Maximum load on cylinder 2: 87990 lb
Maximum load on cylinder 3: 87990 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 7000.0 psi
Compressive strength of cylinder 2: 7000.0 psi
Compressive strength of cylinder 3: 7000.0 psi
Compressive strength (to nearest 10 psi): 7000 psi
General comments (publicly viewable) (Max 1000 characters): Cylinders did not break. Max capacity of compression machine = 7,000 psi.
Test was verified on 12/10/2024 ✔