Summary for Test 2024-11-25-8-1

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 212470
DEA: 044A1304
EFIS: 0400001106
COOP: 042718
DIST-CO-RTE-PM04-SON-101-18.5/18.5
Award Date11/17/2023
Closeout DateNot set
Work DescriptionCONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY
Location DescriptionIN SONOMA COUNTY.
QA Service Level1 (Verified on 09/23/2019)

Sample Information

Sample Taken Date11/25/2024 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/02/2024
Sample typeQuality Assurance A brief description of the sampleHeaded Bar
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMSL Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)056524 Head Manufacturer Lot Number(s)0155, 0226
Rebar Size#10 Headed Bar Model NameLU D14
Size of HeadReduced Size - 4x Head Connection Type
Head ShapeCircular Rebar ManufacturerCascade
Head ManufacturerEaton Steel Head FabricatorErico Lenton
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-18-02

Test Details

DIME Sample ID: 2024-11-25-8
DIME Test ID: 2024-11-25-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2024-12-06

Test Results


Number of Headed Bar Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/02/2024
UTM: NA
Temperature: 0 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1S81-012-241.2711484090430Atlas Technical ConsultantsJ Garland
2S81-012-241.2711952094110Atlas Technical ConsultantsJ Garland
3S81-012-241.2711992094430Atlas Technical ConsultantsJ Garland
4S81-012-241.2711683091990Atlas Technical ConsultantsJ Garland

General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants

Test was verified on 12/6/2024