Summary for Test 2024-07-16-15-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 995157
DEA: 07353904
EFIS: 0718000307
DIST-CO-RTE-PM07-LA-405-17.6
Award Date12/04/2023
Closeout Date08/20/2025
Work DescriptionSEISMIC RETROFIT OF BRIDGE, COMPOSITE COLUMN CASING AND CORE CONCRETE.
Location DescriptionLOS ANGELES COUNTY IN LAWNDALE AT ROUTE 405/107 SEPARATION
QA Service Level1 (Verified on 09/18/2023)

Sample Information

Sample Taken Date07/16/2024 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2024
Sample typeProduction Start-Up A brief description of the sample3/4" HMA -A-SP R25 .75% LAS
The quantity of what the sample constitutes20 BOXES OF HMA, 4 BAGS OF COMBINED AGG, 1 BAG RAP, 4 QTS OF PG58-16, 1 QT LAS From where was the sample collectedManufacturer
First name of sampler or witnessed byJONS Last name of sampler or witnessed byVULCAN QC
Title of sampler Telephone number of sampler
Laboratory sample identification0333A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200M IRW SJR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-07-16-15
DIME Test ID: 2024-07-16-15-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2024-12-05

Test Results


Input Type: Calculated
Tester's full name: Juan Abarca
Date of test: 07/20/2024
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 3.65 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.26 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.03 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/5/2024